• AUTOFLAME燃烧器带程序控制器MMM8002

    详细信息

     品牌:AUTOFLAME  型号:MMM8002  加工定制:否  
     测量范围:11  外形尺寸:111 mm 重量:3 kg 
     用途:燃烧器  产地:德国   
    AUTOFLAME燃烧器带程序控制器MMM8002,AUTOFLAME伺服电机MM10004
    AUTOFLAME电动执行机构MM10005
    AUTOFLAME火焰探测器MM60004/HSU
    AUTOFLAME燃烧控制器MMM8002-MIN50/60H
    elektrogas安全电磁阀 VMR(快开快闭型)VMR3-2 DN25
    elektrogas伊莱克斯紧急切断阀EVRM-NA/6NAEVRM-NC/6NC
    elektrogas安全电磁阀VMR(快开快闭型)VMR3-2 DN25
    elektrogas伊莱克斯紧急切断阀EVRM-NA/6NAEVRM-NC/6NC
    Weishaupt威索伺服电机1055/23,L/A-LFSTG-GAS,
    Weishaupt威索风门执行器1055/231055/80
    Weishaupt威索控制单元显示操作面板WMF20AM20.02
    Weishaupt威索控制器LMV37.410A1WHAZL52.00B1WH
    W-MF10 LM082.120A2WHLMV27.210A2WHW-FM50
    Weishaupt威索温控器 KS40-108-9090E-D51
    Weishaupt威索燃烧器专用伺服电机1055/23,L/A-LFST,燃气伺服G-GAS,
    Weishaup威索燃气阀W-WF-S512 C01 S22W-MF-SE 507 C01 S22
    W-MF 507C  032/P
    Weishaupt威索WDK3/01 S2
    Weishaup威索伺服马达STA13 B0.36/8 2N36L
    9 100mA 仅用于驱动继电器/切换至中性
    120V Unit:
    120V设备
    Outputs Terminal 57 250mA Must be connected through contactor Max Load 5A
    输出 端口 57 250mA 必须通过接触器连接,*大荷载5A
    58 250mA Must be connected through contactor
    58 250mA 必须通过接触器连接
    59 2A 0.6 power factor
    59 2A 0.6 功率因数
    60 2A 0.6 power factor
    60 2A 0.6 功率因数
    61 2A 0.6 power factor
    61 2A 0.6 功率因数
    62 2A 0.6 power factor
    62 2A 0.6 功率因数
    63 2A 0.6 power factor
    63 2A 0.6 功率因数
    78 100mA To drive relay only – switched neutral
    78 100mA 仅用于驱动继电器 切换至中性
    79 100mA To drive relay/lamp only – switched neutral
    79 100mA 仅用于驱动继电器/切换至中性
    Note:
    注意:
    1. The high and low voltage connections are not safe to touch. Protection against electric shock is
    provided by correct installation. CAUTION – ELECTRIC SHOCK HAZARD.
    用手触摸高压和低压连接是危险行为。正确安装电气设备可以防止触电事故。警告:触电危
    险。
    2. Control voltage cabling should be maximum 10m, screened (if not screened then less than 1m,
    however servomotors can be unscreened up to 10m)
    控制电压电缆的*大长度应为10m,经屏蔽(若未屏蔽应短至1米);伺服马达的未屏蔽电缆
    *大长度可为10m
    3. Any cabling over 10m must have additional surge protection.
    所有超过10m的电缆必须配备电涌保护。
    4. Low voltage cables should be screened cable as specified in section 1.3.3.
    低压电缆应符合章节1.3.3规定的经屏蔽电缆。
    5. The burner ‘High Limit Stat’ must be a manual reset type.
    燃烧器的“上限启停控制器”必须为手动复位型。
    Note: There is a lid (back plate) fitted onto the back of the Mini Mk8 M.M. with a Warning label to
    prevent any unauthorised fuse replacements.